Table Of ContentACCESSORY CATALOGUE UK and Ireland
Issue 2
www.trylon.com
ABOUT US
Anixter is a leading global supplier of communications and security
products and electrical and electronic wire and cable. We help our
customers specify solutions and make informed purchasing decisions
around technology, applications and relevant standards. Throughout
the world, we provide innovative supply chain management solutions to
reduce our customers’ total cost of production and implementation.
“ Anixter’s value to customers can be summed up in the
depth and breadth of our inventory, application-specific
technical and product knowledge, and a wide array
of inventive Supply Chain Solutions mapped to our
customers’ specific requirements.”
Bob Eck, President & CEO
ANIXTER IS A PROUD DISTRIBUTOR OF TRYLON PRODUCTS.
UNITED KINGDOM AND IRELAND
INDUSTRIAL
Aberdeen Oil and Gas Tel: +44 (0)1224 275680
Birmingham Construction Tel: +44 (0)121 322 7140
Dublin Construction Tel: +353 1 257 2000
Glasgow Construction Tel: +44 (0)1698 503810
Uxbridge Construction Tel: +44 (0)845 604 1301
Warrington Construction Tel: +44 (0)1925 810121
Warrington Rail Tel: +44 (0)870 242 2822
anixter.co.uk
anixter.ie
OEM
Barrow-in-Furness Tel: +44 (0)1229 825871
Chesterfield Tel: +44 (0)1246 451600
Coventry Tel: +44 (0)24 7646 5829
Diss Tel: +44 (0)1379 643506
Glasgow Tel: +44 (0)141 445 2193
Leeds Tel: +44 (0)113 244 0321
Liverpool Tel: +44 (0)151 355 2211
Luton Tel: +44 (0)1582 498900
Newcastle Tel: +44 (0)191 482 7660
Plymouth Tel: +44 (0)1752 341100
Portsmouth Tel: +44 (0)23 9286 5469
Sheffield Tel: +44 (0)1142 709300
Warrington Marine
and Defence Tel: +44 (0)1925 816166
anixter.co.uk
FOR FURTHER INFORMATION CONTACT
YOUR LOCAL ANIXTER REPRESENTATIVE.
GLOBAL REACH. LOCAL ADVANTAGE.
With Anixter, you get a true local partner around the world. No other distributor of our
kind can claim an in-country presence in more than 50 countries and 300 cities.
We do business in more than 35 currencies and 30 languages, which
means we are uniquely positioned to help facilitate your project in
the local environment, reduce risks and keep costs down.
CORPORATE SNAPSHOT
5OV0ER 270
NUMBER OF APPROXIMATELY
1YEAR9 FO5UND7ED EMPLOYEES 100,000
APPROXIMATELY
WAREHOUSES/
9,100 COUNTRIES CUSTOMERS BRANCHES
IN
APPROXIMATELY 300 STOACKX SYEMBOL 500,000 5F0OR0TUNE
$$1.1 BILLION
PRODUCTS
LIST
CITIES
INVENTORY
DIFFERENT WAYS TO BUY FROM ANIXTER
eAnixter.com
PHONE, FAX, B2B INTEGRATION EPROCUREMENT ANIXTER.COM
EMAIL WITH (E.G., EDI, JIT, ERP PUNCHOUT CATALOG (RETAIL PRICING)
SALES REP SYSTEMS) (E.G., ARIBA, SCIQUEST)
EANIXTER.COM
CUSTOM CATALOG (CONTRACT PRICING)
(E.G., INTELLIBID, ACCUBID)
CUSTOMER BRANDED PHYSICAL STORES ELECTRONIC INVOICES AUTOMATED ORDER
E-COMMERCE WEBSITE AND PAYMENTS CONFIRMATION AND
(CONTRACT PRICING) CONSOLIDATED INVOICE SHIPMENT NOTIFICATION
STATEMENTS
Major enhancements coming soon.
Anixter Inc. World Headquarters Wire & Cable EMEA Headquarters
2301 Patriot Boulevard Unit A, The Beacons
Glenview, Illinois 60026 Birchwood Park
224.521.8000 Birchwood, Warrington
Cheshire, WA3 6GP
+44 (0) 1925 838658
TABLE OF CONTENTS
Table of Contents
CE Product Cer(cid:415) fi ca(cid:415) on Example ....................6 2-Way RRU Mount ........................................30
Mount Calcula(cid:415) on Example ............................7 3-Way RRU Mount ........................................31
Antenna/MW Standoff Mounts ......................8 4-Way RRU Mount ........................................32
Yoke Bracket Mount .......................................9 Installa(cid:415) on Drawings ....................................33
Antenna/MW Standoff Mount Installa(cid:415) on ..............................33
Light Duty Wall Mount Assembly ..................10
Yoke Bracket Mount Installa(cid:415) on ...............................................36
Yoke Bracket Mount Without Pipe Installa(cid:415) on .........................37
Wall Mount Assembly ..................................11
Light Wall Mount Installa(cid:415) on ...................................................38
Wall Mount Installa(cid:415) on ............................................................39
Corner Mount Assembly ...............................12
Corner Mount Installa(cid:415) on ........................................................40
Pipe Extension Assembly Installa(cid:415) on .......................................41
Pipe Extension Assembly ..............................13 3-Pipe 3-Sector Spine Mount Installa(cid:415) on .................................42
3-Pipe 3-Sector Spine Mount Without Pipe Installa(cid:415) on ...........43
3-Pipe 3-Sector Spine Mount ........................14 6-Pipe 3-Sector Spine Mount Installa(cid:415) on .................................44
6-Pipe 3-Sector Spine Mount Without Pipe Installa(cid:415) on ...........45
6-Pipe 3-Sector Spine Mount ........................15 Pole Ring Standoff Installa(cid:415) on ..................................................46
Pole Ring Standoff Without Pipe Installa(cid:415) on ...........................47
Pole Ring Standoff ........................................16 2-Level Pole Ring Standoff Installa(cid:415) on .....................................48
2L 6P Pole Ring Standoff Installa(cid:415) on ........................................49
Light Duty Roof Ballast Mount Installa(cid:415) on ...............................50
2-Level Pole Ring Standoff ............................17
Single Pipe Roof Ballast Mount Installa(cid:415) on ..............................51
Double Pipe Roof Ballast Mount Installa(cid:415) on ............................52
2L 6P Pole Ring Standoff ...............................18
4-Hole Feeder Bracket Installa(cid:415) on ...........................................54
6-Hole Feeder Bracket Installa(cid:415) on ...........................................55
Bulk Pipe ......................................................19
Gantry poles Installa(cid:415) on ..........................................................56
Fixed Cross Over Assemblies Installa(cid:415) on..................................57
Light Duty Roo(cid:332) op Ballast Mount .................20 Universal Fixed Cross Over Assemblies Installa(cid:415) on ..................59
2-Way RRU Mount Installa(cid:415) on .................................................60
Single Pipe Roof Ballast Mount .....................21 3-Way RRU Mount Installa(cid:415) on .................................................61
4-Way RRU Mount Installa(cid:415) on .................................................62
Double Pipe Roof Ballast Mount ...................22
Trylon Also Off ers .........................................64
Step Bolt Assembly .......................................24
4-Hole Feeder Bracket ..................................25
6-Hole Feeder Bracket ..................................26
Gantry Poles .................................................27
Fixed Crossover Assembly .............................28
Universal Fixed Crossover Assembly .............29
[email protected] www.trylon.com
4
CE PRODUCT CERTIFICATION
EXAMPLE
Identification No. 1381 of Notified Body
Trylon TSF
21 South Field Drive
Elmira, Ontario
Canada
N2B 0A6
14
Kit Part #4.927.0103.001
Essential Characteristics Declared Performance Harmonized
Technical
Specification
Tolerances on dimensions and In accordance with EN 1090-2 EN 1090-1:2009
shape
Weldability Based in S355JR Material, Max
CEV % is 0.543
Fracture toughness / brittle As per EN 10025:2004
strength requirements for S275JR &
S355JR steel - 27 J at 20° C
Impact resistance See Above.
Load bearing capacity As per EN-1993-3-1 (2007),
Minimum capacity is 4.2kN
Deformation at serviceability As per EN-1993-3-1 (2007),
limit state Maximum deflection is 0.6mm
Fatigue strength NPD
Resistance to fire As per EN-13501-1, REI 180
Reaction to fire As per EN-13501-2, A1
Release of Cadmium and its NPD
compounds
Emission of Radioactivity NPD
Durability All products Galvanized to
European EN ISO 1461
[email protected] www.trylon.com
5
CE PRODUCT CERTIFICATION
EXAMPLE
Declaration of Performance
(according to REGULATION (EU) No 305/2011)
Kit Description: MW Standoff Mount (1m Pipe)
Kit Part Number: 4.927.0103.001
DoP Number: 4.927.0103.001
Applicable Harmonized Standard: EN 1090-1:2009
Intended Usage: Antenna Support Mount
Manufacturer Information:
Trylon TSF
21 South Field Drive
Elmira, Ontario
Canada
N2B 0A6
Tel: (519) 669 – 5421
Website: www.Trylon.com
CE Marking Notified Body:
SGS Italia S.p.A.
Via G. Gozzi 1/a
Milan, 20129
Italy
Tel: +39 02 73 931
Website: www.sgsgroup.it/
System of assessment and verification of constancy
of performance of the product: EXC2
Notified factory production control certification body
No. 1381 performed the initial inspection of the manufacturing
plant and of factory production control and the continuous surveillance,
assessment, and evaluation of factory production control and issued
the certificate of conformity of the factory production control
Stephanie Berry Date: June 29, 2015
Director of Product Operations
Trylon
[email protected] www.trylon.com
6
MOUNT CALCULATION
EXAMPLE
Antenna/MW Standoff Mount (0.5m Pipe)
With Medium Backings
Kit # 4.927.0108.001
21 South Field Drive, PO Box 186 Design Code: BS8100
Elmira, Ontario, Canada N3B 2Z6
519-669-5421 (ph), 519-669-8912 (fx)
INPUT VALUES
1) SITE AND TOWER PARAMETERS
Wind Speed* 24.0 m/s
Tower Height 60.0 m
Antenna Elevation* 60.0 m
Site Altitude 100 m
2) ANTENNA
Antenna Type* r (Flat,Round)
Height of Antenna* 1.50 m
Width of Antenna* 0.50 m
Weight of Antenna* 50.0 kg
3) MOUNT OPTIONS
Number of Mounting Angles* 1 (1 or 2)
OK!
Length of Horizontal Pipe* 0.5 m (0.5, 1, 2 or 3)
Backing* Medium (Medium, Small)
4) MAX ALLOWABLE ANTENNA DEFLECTION
PLAN VIEW Relative to tower/wall* 5.00 mm
ELEVATION VIEW
SUMMARY of RESULTS
DESIGNED TO: 24M/S WIND SPEED
(1) 1.5M x0.5M ANTENNA
Results Capacity
Vertical Pipe Bend Check 500mm LONG x 76mm OD x 6mm THK [345MPa] 21.71 MPa 310.28 MPa
PASS[1.7%]
Horizontal Angle Bend Check 64mm x 64mm x 6mm, 613mm LONG [300MPa] 228.79 MPa 273.04 MPa
PASS[83.8%]
Backing Channel Bend Check 260mm LONG x 44mm WIDE x 57mm DEEP x 5mm THK [300MPa] 111.15 MPa 273.04 MPa
PASS[40.7%]
Backing Rod Combined Shear & Tension Check
PASS[8.2%]
Tower Leg Reactions Per Backing Horizontal 1.35 kN
Vertical 0.63 kN
Torsional Moment 0.52 kN.m
Total mount Deflection 0.55 mm PASS
APPROX. MOUNT WEIGHT: 0.60 kN (Antenna and tower connection included)
Assumptions:
- Areas calculated usings BS8100 guidelines - Quality Class: A
- Design based on 50 year return basic wind speed - Terrain Category: III (Typ UK farmland)
- Environment Conditions: Adjacent to Main Road - Checked Design for Member Stresses
- Usage: Broadcasting - S values are calculated using std tables/formulas
- Antenna centrally located on vertical Pipe - Atmospheric environment assumed to by Type (a) as per BS8100, cl. 3.1.1
[email protected] www.trylon.com
7
ANTENNA/MW STANDOFF
MOUNTS
Kit # Description Qty Weight (kg)
4.927.0108.001 MW Standoff Mount (76mm OD x 0.5m Pipe) Each 13.2 kg
4.927.0103.001 MW Standoff Mount (76mm OD x 1m Pipe) Each 24.5 kg
4.927.0103.002 MW Standoff Mount (76mm OD x 2m Pipe) Each 36.0 kg
4.927.0103.003 MW Standoff Mount (76mm OD x 3m Pipe) Each 47.7 kg
4.927.0103.101 MW Standoff Mount (Without Pipe) Each 14.7 kg
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS8100
30m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Length of Pipe (0.5m) - Round / Flat
1.41 m2 1.23 m2 1.08 m2 1.26 m2 1.10 m2 0.96 m2
0.61 m2 0.52 m2 0.44 m2 0.54 m2 0.45 m2 0.39 m2
Length of Pipe (1m) - Round / Flat
3.95 m2 2.45 m2 2.15 m2 2.52 m2 2.19 m2 1.92 m2
1.24 m2 1.05 m2 0.89 m2 1.08 m2 0.91 m2 0.78 m2
Allowable Antenna
Length of Pipe (2m) - Round / Flat
Loading
2.74 m2 2.39 m2 2.10 m2 2.46 m2 2.14 m2 1.87 m2
1.20 m2 1.02 m2 0.87 m2 1.05 m2 0.89 m2 0.76 m2
Length of Pipe (3m) - Round / Flat
2.67 m2 2.33 m2 2.05 m2 2.40 m2 2.08 m2 1.82 m2
1.17 m2 0.99 m2 0.85 m2 1.02 m2 0.86 m2 0.74 m2
NOTES:
1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.
2) Mount assumed at top tower.
3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.1
4) Assumed 50.0 kg antenna weight per square meter of antenna area.
5) See pages 33, 34, and 35 for Installation Drawings
[email protected] www.trylon.com
8
YOKE BRACKET MOUNT
Kit # Description Qty Weight (kg)
4.927.0102.001 2-Pipe Yoke Bracket Mount (60mm OD x 3m Pipe) Each 77.0 kg
4.927.0102.101 2-Pipe Yoke Bracket Mount (Without Pipe) Each 44.9 kg
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS8100
30m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna 3.93 m2 3.25 m2 2.73 m2 3.38 m2 2.79 m2 2.34 m2
Loading per Pipe
NOTES:
1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.
2) Antenna assumed at top tower.
3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.1
4) Assumed 50.0 kg antenna weight per square meter of antenna area.
5) See pages 36 and 37 for Installation Drawings
[email protected] www.trylon.com
9
Description:ABOUT US Anixter is a leading global supplier of communications and security products and electrical and electronic wire and cable. We help our